2012 · NEW ENGLAND JOURNAL OF MEDICINE

Registry of Transcatheter Aortic-Valve Implantation in High-Risk Patients

Gilard, Martine, Eltchaninoff, Helene, Iung, Bernard, Donzeau-Gouge, Patrick, Chevreul, Karine, Fajadet, Jean, Leprince, Pascal, Leguerrier, Alain, Lievre, Michel, Prat, Alain, Teiger, Emmanuel, Lefevre, Thierry, Himbert, Dominique, Tchetche, Didier, Carrie, Didier, Albat, Bernard, Cribier, Alain, Rioufol, Gilles, Sudre, Arnaud, Blanchard, Didier, Collet, Frederic, Dos Santos, Pierre, Meneveau, Nicolas, Tirouvanziam, Ashok, Caussin, Christophe, Guyon, Philippe, Boschat, Jacques, Le Breton, Herve, Collart, Frederic, Houel, Remi, Delpine, Stephane, Souteyrand, Geraud, Favereau, Xavier, Ohlmann, Patrick, Doisy, Vincent, Grollier, Gilles, Gommeaux, Antoine, Claudel, Jean-Philippe, Bourlon, Francois, Bertrand, Bernard, Van Belle, Eric, Laskar, Marc, FRANCE 2 Investigators

Journal
NEW ENGLAND JOURNAL OF MEDICINE
Année
2012
Volume
366
Numéro
18
Pages
1705-1715
Mois
MAY 3
DOI
10.1056/NEJMoa1114705

Abstract

Background Transcatheter aortic-valve implantation (TAVI) is an emerging intervention for the treatment of high-risk patients with severe aortic stenosis and coexisting illnesses. We report the results of a prospective multicenter study of the French national transcatheter aortic-valve implantation registry, FRANCE 2. Methods All TAVIs performed in France, as listed in the FRANCE 2 registry, were prospectively included in the study. The primary end point was death from any cause. Results A total of 3195 patients were enrolled between January 2010 and October 2011 at 34 centers. The mean (+/- SD) age was 82.7 +/- 7.2 years; 49% of the patients were women. All patients were highly symptomatic and were at high surgical risk for aortic-valve replacement. Edwards SAPIEN and Medtronic CoreValve devices were implanted in 66.9% and 33.1% of patients, respectively. Approaches were either transarterial (transfemoral, 74.6%; subclavian, 5.8%; and other, 1.8%) or transapical (17.8%). The procedural success rate was 96.9%. Rates of death at 30 days and 1 year were 9.7% and 24.0%, respectively. At 1 year, the incidence of stroke was 4.1%, and the incidence of periprosthetic aortic regurgitation was 64.5%. In a multivariate model, a higher logistic risk score on the European System for Cardiac Operative Risk Evaluation (EuroSCORE), New York Heart Association functional class III or IV symptoms, the use of a transapical TAVI approach, and a higher amount of periprosthetic regurgitation were significantly associated with reduced survival. Conclusions This prospective registry study reflected real-life TAVI experience in high-risk elderly patients with aortic stenosis, in whom TAVI appeared to be a reasonable option. (Funded by Edwards Lifesciences and Medtronic.)

Lire l'article complet